Wind engineering aspects of the Storebælt suspension bridge with a main span of 1624 m. Wind tunnel tests for determination of structural vibrations, wind load, and wind-induced traffic accidents were carried out. An estimation of extreme winds at the Storebælt site was also performed. Wind buffeting, flutter and vortex-induced vibrations were part of the structural vibrations investigated. Theoretical calculations and interpretation of wind tunnel test results were carried out. Clients: Steinman Boynton Gronquist & Birdsall (today Parsons Corporation) and A/S Storebæltsforbindelsen (today A/S Storebælt)