Loading...

Wind engineering aspects on The Icelandic National Concert and Conference Centre in Reykjavik. The Centre is 28.000 square meters in size and 43 meters tall. Local 1 square meter and 10 square meter wind loads compatible with the format of the Eurocode, representative wind loads on larger parts of the building and global wind loads on the building were determined. Determination of relevant dynamic wind loads for the special structural components in the facade. The wind environment of the site was investigated. Client: Rambøll